Variable Induction Control Valve: Service and Repair

MANIFOLD TUNE VALVE

REMOVAL 

1. Disconnect negative battery cable. 

Fig.13 Manifold Tuning Value

2. Disconnect electrical connector (Fig. 13). 
3. Remove manifold tuning valve mounting screws. Remove tuning valve. 

INSTALLATION

1. Install tuning valve. Tighten mounting screws to 11.9 N.m (105 in.lbs.) torque. 
2. Install electrical connector. 
3. Connect negative battery cable.