chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Front Blower Motor|Page 5764 > < Front Blower Motor
Page 2
background image

Blower Motor Wire Lead Grommet

9. Push the rubber blower motor wire lead grommet through the opening in the lower air inlet housing.

10. Feed the blower motor wire lead through the opening in the lower air inlet housing and remove the lower air inlet housing from the vehicle.
11. Position the recirculation-air door as necessary to access and remove the three screws that secure the blower motor to the lower half of the HVAC

housing.

12. Gently flex the recirculation air door far down enough to remove the blower motor and wheel from the HVAC housing.

Blower Motor Mounting Tabs

13. Remove the blower motor and wheel from the HVAC housing. Note the position of the blower motor mounting tabs.

INSTALLATION

1. Position the blower motor and wheel to the lower half of the HVAC housing. Align the blower motor mounting tabs to the correct location on the

HVAC housing.

2. Gently flex the recirculation-air door far down enough to install the blower motor and wheel into the HVAC housing.
3. Position the recirculation-air door as necessary to install the three screws that secure the blower motor to the HVAC housing. Tighten the screws to

2 N.m (17 in. lbs.).

4. Feed the blower motor wire lead through the opening in the lower air inlet housing and seat the rubber grommet into the lower air inlet housing.
5. Position the recirculation-air door pivot into the lower air inlet housing.
6. Install the four screws (from the bottom) that secure the lower air inlet housing to the upper air inlet housing and the lower HVAC housing.

Tighten the screws to 2 N.m (17 in. lbs.).

7. Install the one screw (from the top) that secures the lower air inlet housing to the upper air inlet housing. Tighten the screws to 2 N.m (17 in. lbs.).

Front Blower Motor|Page 5764 > < Front Blower Motor