chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

A/C - Musty Odors When Hot/Humid|Page 5883 > < A/C - Musty Odors When Hot/Humid|Page 5881
Page 1
background image

Evaporator Core: Description and Operation

A/C Evaporator

The A/C evaporator is located within the HVAC housing, behind the instrument panel. The A/C evaporator and insulator are positioned in the HVAC
housing so that all air entering the housing must pass over the evaporator fins before it is distributed through the heating-A/C system ducts and outlets.
However, air passing over the evaporator fins will only be conditioned when the A/C compressor is engaged and circulating refrigerant through the A/C
evaporator.

The A/C evaporator tubes are connected and sealed to the A/C expansion valve by use of rubber O-rings and a tapping block.

The A/C evaporator can only be serviced by removing and disassembling the HVAC housing.

Refrigerant enters the A/C evaporator from the A/C expansion valve as a low-temperature, low-pressure mixture of liquid and gas. As air flows over the
fins of the A/C evaporator, the humidity in the air condenses on the fins, and the heat from the air is absorbed by the refrigerant. Heat absorption causes
the refrigerant to boil and vaporize. The refrigerant becomes a low-pressure gas when it leaves the A/C evaporator.

The A/C evaporator cannot be repaired and, if faulty or damaged, it must be replaced.