chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC > < Component Locations|Page 782
Page 2
background image

1. Disconnect and isolate the negative battery cable. 
2. Remove the instrument panel from the vehicle. 
3. Disconnect the wire harness connector from the evaporator temperature sensor located on the top of the HVAC housing. 
4. Remove the evaporator temperature sensor from the HVAC housing.

INSTALLATION

EARLY MODEL YEAR

NOTE: Any grease removed with the evaporator temperature sensor must be replaced. Failure to do so could result in poor A/C performance. 

1. Position the evaporator temperature sensor into the right rear corner of the engine compartment. 
2. Reconnect the wire harness connector to the evaporator temperature sensor. 
3. Position the evaporator temperature sensor onto the top of the expansion valve with the sensor probe inserted into the well in the expansion valve. 
4. Install the temperature sensor retainer. 
5. Reinstall the air cleaner housing into the right side of the engine compartment. 
6. Reconnect the battery negative cable. 
7. Run the HVAC Cool Down test to verify system is operating properly.

LATE MODEL YEAR

1. Install the evaporator temperature sensor into the top of the HVAC housing.
2. Connect the wire harness connector to the evaporator temperature sensor. 
3. Install the instrument panel. 
4. Reconnect the battery negative cable. 
5. Run the HVAC Cool Down test to verify system is operating properly.

Refrigerant Pressure Sensor / Switch, HVAC > < Component Locations|Page 782