chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Recirculation Door Actuator - Removal|Page 5767 > < Recirculation Door Actuator - Removal
Page 1
background image

Air Door Actuator / Motor: Service and Repair
Recirculation Door Actuator - Installation

INSTALLATION

1. Position the recirculation door actuator (1) into the vehicle.
2. Install the recirculation door actuator onto the left side of the HVAC air inlet housing (2). If necessary, rotate the actuator slightly to align the pin

on the actuator lever (4) with the groove in the recirculation door lever (3).

3. Position the right floor distribution duct (1) out of the way and install the screws (5) that secure the recirculation door actuator (2) to the air inlet

housing (3). Tighten the screws to 2 Nm (17 in. lbs.).

4. Connect the wire harness connector (4) to the recirculation door actuator.

Recirculation Door Actuator - Removal|Page 5767 > < Recirculation Door Actuator - Removal