Transmission Temperature Sensor/Switch: Testing and Inspection

CONTINUITY CHECK

1. Disconnect the transaxle range sensor connector.
2. Measure the resistance between terminals 2-3 and check that the values are as shown below.

Standard values:

Oil temperature: 0° C (32° F)

Resistance value: 29.33 - 35.99 kilo ohms

Oil temperature: 100° C (212° F)

Resistance value: 640 - 720 kilo ohms

3. If the values are outside the standard values, replace the transaxle range sensor.