Sebring Convertible V6-2.7L Flex Fuel (2008)
5. Remove the instrument panel and place it on a workbench See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service
and Repair/Instrument Panel - Removal.
6. Remove the left and right instrument panel air outletsSee: Air Register/Service and Repair/Air Outlets - Removal.
7. Remove the outer instrument panel ducts.
8. Remove the instrument panel top pad See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service and Repair/Instrument
Panel Pad - Removal.
9. Remove the demister ducts See: Instrument Panel Demister Ducts - Removal.
10. Remove the defroster duct See: Defroster Ducts - Removal.
11. Remove the screws (3) that secure the center instrument panel duct (1) to the instrument panel top cover (2).
12. Disengage the center instrument panel duct from the instrument panel top cover and remove the duct.
Instrument Panel Ducts - Installation
INSTALLATION
NOTE: LHD Chrysler model shown in illustrations. Dodge and RHD models similar.
OUTER DUCTS