8. Verify that the Actuator Calibration of the Front Control has passed. If an Actuator Calibration has not passed correct any errors before proceeding
further.
9. Rotate the Rear Temperature Selector counter clockwise to the Cold Position, allow the Selector to remain in the Cold Position for 5 seconds.
10. Rotate the Rear Temperature Selector Clockwise to the Hot Position, allow the Selector to remain in the Cold Position for 5 seconds.
11. Calibration is now complete.