chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Removal and Replacement|Page 5759 > < Removal and Replacement|Page 5757
Page 4
background image

Lower Air Inlet Housing

2. Remove the recirculation door actuator.
3. Remove the recirculation door actuator wire lead from the routing clip located on the lower air inlet housing and position the wire lead aside.
4. Disconnect the blower motor wire lead connector from the blower motor resistor or power module, depending on application.
5. Remove the one screw (from the top) that secures the lower air inlet housing to the upper air inlet housing.
6. Remove the four screws (from the bottom) that secure the lower air inlet housing to the upper air inlet housing and remove the lower HVAC

housing.

Blower Motor Wire Lead Grommet

7. Push the rubber blower motor wire lead grommet through the opening in the lower air inlet housing.
8. Feed the blower motor wire lead through the opening in the lower air inlet housing and remove the lower air inlet housing from the vehicle.

Removal and Replacement|Page 5759 > < Removal and Replacement|Page 5757