chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Removal and Replacement|Page 5763 > < Removal and Replacement|Page 5761
Page 8
background image

rear floor panel behind the right rear wheel housing.

6. Disengage the metal retaining strap from the sealing plate and disconnect the underbody refrigerant extension lines from the rear A/C expansion

valve.

7. Remove and discard the O-ring seals from the underbody refrigerant line fittings.
8. Install plugs in, or tape over the opened underbody refrigerant line fittings and rear expansion valve ports.

Underbody Heater Line Rear Quick Connect Fittings

9. Disconnect the underbody heater lines from the rear heater core tubes which extend through the rear floor panel in front of the right rear wheel

housing by releasing the insert in each rear quick connect fitting and carefully pulling downward on the fittings while using a slight twisting
motion.

10. Lower the vehicle.
11. Remove right rear quarter panel and D-pillar trim panels.
12. Remove the metal support strap from the rear quarter panel and floor.
13. Remove the rear floor distribution duct.
14. Remove the rear ceiling distribution ducts.

Removal and Replacement|Page 5763 > < Removal and Replacement|Page 5761