4. Install the recirculation-air door into the lower air inlet housing.

5. Install the four screws (from the bottom) that secure the lower air intake housing to the lower half of the HVAC housing. Tighten the screws to 2

Nm (17 in.lbs).

6. Install the one screw that secures the upper intake air housing to the lower intake air housing. Tighten the screw to 2 Nm (17 in.lbs).

7. Install the recirculation door actuator. Make certain that the splines are aligned with the recirculation-air door pivot. Install the two screws that

secure the recirculation door actuator to the housing. Tighten the screws to 2 Nm (17 in.lbs). Route the wiring into the molded routing clips.

8. Connect the wire harness connector to the blower motor resistor block or blower motor power module, depending on application.

9. Install the HVAC Housing. Refer to 