10. Mate the A/C system hose connector block to the compressor. Hold it in place while tightening the retaining nut.

Tighten
Tighten the A/C system hose connector retaining nut to 33 Nm (24 lb.ft).

11. Connect the negative battery cable.
12. Evacuate and recharge the A/C system.

Housing Assembly HVAC > < A/C High-Pressure Line|Page 3770