Leganza CDX L4-2.2L DOHC D-TEC MFI (1999)
7. Remove the auxiliary catalytic converter lower flange bolts.
8. Remove the connecting pipe mounting bracket bolts and bracket.
9. Remove the auxiliary catalytic converter.
INSTALLATION PROCEDURE
1. Fit the auxiliary catalytic converter onto the connecting pipe, raise the connecting pipe, and install the connecting pipe mounting bracket nuts and
bracket.
Tighten
Tighten the connecting pipe mounting bracket nuts to 30 Nm (22 ft. lbs.).