daewoo Workshop Repair Guides

Daewoo Workshop Service and Repair Manuals

Restraint Systems > < Vacuum Reservoir HVAC|Service and Repair
Page 2
background image

1. Place the vacuum tank against the bulkhead over the mounting studs.
2. Secure the tank with the mounting nuts.

Tighten
Tighten the vacuum tank mounting nuts to 4 N.m (35 lb-in).

3. Install the vacuum hoses.

IMPORTANT:  The line to the intake manifold goes onto the bottom port, marked S. There is a check valve to maintain the vacuum for heater
control during temporary losses of vacuum in the intake manifold. If the connections are reversed, the controls will not function properly.

Restraint Systems > < Vacuum Reservoir HVAC|Service and Repair