Daytime Running Lamp Control Module
Removal Procedure
1. Disconnect the negative battery cable.
2. Remove the HVAC controls.
3. Remove the ashtray.
4. Remove the screws and the daytime running lamp module.
5. Disconnect the electrical connector.
Installation Procedure
1. Connect the electrical connector.
2. Install the daytime running lamp module with the screws.
Tighten
Tighten the daytime running lamp module screws to 4 N.m (35 lb-in).
3. Install the ashtray.
4. Install the HVAC controls.
5. Connect the negative battery cable.