Nubira CDX Sedan L4-2.0L DOHC D-TEC MFI (1999)
3. Install the Torx head bolts securing the solenoid.
Tighten
Tighten the ABS solenoid Torx head bolts to 4.5 Nm (40 inch lbs.).
4. Connect the solenoid electrical connector.
Important: Make sure that the solenoid electrical connectors are correctly installed.
5. Connect the negative battery cable.
6. Bleed the brake system. See: Brake Bleeding
Hydraulic Modulator Bleeder Valve
Removal Procedure
1. Place a shop cloth or suitable container below the bleeder valve to catch escaping brake fluid.