daewoo Workshop Repair Guides

Daewoo Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC|Diagrams|Page 167 > < Refrigerant Pressure Sensor / Switch, HVAC|Diagrams
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair

Removal Procedure

1. Disconnect the negative battery cable.
2. Remove the air cleaner housing.

2.1 Disconnect the hose to the intake manifold.
2.2 Remove the air cleaner housing retaining bolts.
2.3 Lift out the housing.

3. Discharge and recover the refrigerant.
4. Release the connector lock and pull the transducer wire connector out.

5. Remove the transducer with a wrench.
6. Discard the O-ring seal.

Installation Procedure