Nubira SX Wagon L4-2.0L DOHC D-TEC MFI (1999)
Blower Motor Resistor: Service and Repair
Removal Procedure
1. Disconnect the negative battery cable.
2. Remove the glove box.
3. Remove the footwell upper cover.
4. Disconnect the electrical connector at the resistor.
5. Remove the screws from the resistor.
6. Remove the resistor from the heater/air distributor case by gently pulling the resistor downward.
Installation Procedure
1. Install the new resistor into the heater/air distributor case with the screws.
Tighten
Tighten the blower resistor retaining screws to 6 Nm (53 lb.in).
2. Connect the electrical connector at the resistor.
3. Connect the negative battery cable.
4. Confirm the proper performance of the blower.
5. Replace the footwell upper cover.
6. Replace the glove box.