Avenger V6-2.7L Flex Fuel (2009)
Connector, Ground and Splice Information
CONNECTOR, GROUND AND SPLICE INFORMATION
CAUTION: Not all connectors are serviced. Some connectors are serviced only with a harness. A typical example might be the Supplemental
Restraint System connectors. Always check parts availability before attempting a repair.
IDENTIFICATION
In-line connectors are identified by a number, as follows:
-
In-line connectors located in the engine compartment are C100 series numbers.
-
In-line connectors located in the instrument panel area are C200 series numbers.
-
In-line connectors located in the body are C300 series numbers.
-
Jumper harness connectors are C400 series numbers.
-
Grounds and ground connectors are identified with a "G" and follow the same series numbering as the in-line connectors.
-
Splices are identified with an "S" and follow the same series numbering as the in-line connectors. In addition, S001-S099 numbers are located in
the engine compartment.
-
Component connectors are identified by the component name instead of a number. Multiple connectors on a component use a C1, C2, etc.
identifier.
LOCATIONS
Section 8W-91 contains connector/ground/splice location illustrations. The illustrations contain the connector name (or number)/ground number/splice
number and component identification. Connector/ground/splice location charts in section 8W-91 reference the figure numbers of the illustrations.
The abbreviation T/O is used in the component location section to indicate a point in which the wiring harness branches out to a component. The
abbreviation N/S means Not Shown in the illustrations
Section Identification and Information
SECTION IDENTIFICATION AND INFORMATION
The wiring diagrams are grouped into individual sections. If a component is most likely found in a particular group, it will be shown complete (all wires,
connectors, and pins) within that group. For example, the Auto Shutdown Relay is most likely to be found in Group 30, so it is shown there complete. It
can, however, be shown partially in another group if it contains some associated wiring.