B350 1 Ton Van V8-318 5.2L VIN Y FI (1988)
Blower Motor Switch: Customer Interest
Heater/AC Blower Motor Fan Switch - Inoperative
NO.:
24-03-92
GROUP:
Heater & A/C
DATE:
Aug. 24, 1992
SUBJECT:
Inoperative Heater/AC Blower Motor Fan Switch
MODELS:
1986-1988
(B) Ram Van/Wagon
1989-1992
(AB) Ram Van/Wagon
SYMPTOM/CONDITION:
Customer complaints of inoperative blower motor switch or repeated blown fuses. This condition occurs most often if the blower is operated on the
"high" blower position.
PARTS REQUIRED:
1
Blower Motor Switch Package
4723982
Package Contents:
1
Blower Motor Wiring Assembly with Relay
4723644
5
Tie Straps
6015756
1
Instruction Sheet
1
Heat Shrink Tubing
4419644
REPAIR PROCEDURE:
This repair involves replacement of blower motor switch with a revised switch and installation of a wiring harness with relay assembly.
1.
With ignition key in the OFF position, disconnect the negative battery cable.
2.
Remove the steering column cover as outlined in the appropriate service manual, see Figure 1.