background image

Fluid Pump: Description and Operation

The oil pump is located in the pump housing inside of the bell housing of the transaxle case, and is similar to oil pumps used in other Chrysler
applications. The inner gear is driven by the torque converter impeller hub. Torque is supplied to the impeller hub by the engine crankshaft through the 
flex plate and converter housing.

As the gears rotate, the clearance between the gear teeth increases in the crescent area, and creates a suction at the inlet side of the pump. Fluid is pulled
through the pump inlet from the oil pan. As the clearance between the gear teeth in the crescent area decreases, it forces fluid into the pump outlet. The
pressurized oil from the outlet operates the torque converter, clutches and the lubrication system. The pump is held in the housing by the reaction shaft
support