dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

42RLE Automatic Transmission|Page 4924 > < 42RLE Automatic Transmission|Page 4922
Page 4
background image

The solenoid switch valve  controls line pressure from the LR/CC solenoid (4). In one position, it allows the low/reverse clutch to be pressurized. In the
other, it directs line pressure to the converter control and converter clutch valves (7).

MANUAL VALVE

The manual valve (4) is operated by the mechanical shift linkage. Its primary responsibility is to send line pressure to the appropriate hydraulic circuits
and solenoids. The valve has three operating ranges or positions.

CONVERTER CLUTCH SWITCH VALVE

42RLE Automatic Transmission|Page 4924 > < 42RLE Automatic Transmission|Page 4922