1. Install the Sort Runner Valve. Align the slot in the valve with the tab on the intake manifold shaft.
2. Install the 2 mounting bolts.
3. Tighten bolts to 2.8 N.m (25 in. lbs.).

4. Connect the electrical connector.
5. Connect negative battery cable.