dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Duct-Floor Console|Page 8921 > < Duct-Floor Console|Page 8919
Page 8
background image

1. Remove the instrument panel and place it on a workbench.

2. Remove the screw that secures the instrument panel top pad (1) to the reinforcement bracket (2).

3. Remove the four screws that secure the driver side instrument panel duct and demister duct assembly (3) to the instrument panel and remove the

duct assembly.

4. Remove the four screws that secure the passenger side instrument panel duct and demister duct assembly (4) to the instrument panel and remove

the duct assembly.

Installation

INSTALLATION

NOTE:  LHD model shown. RHD model similar.

1. Position the passenger side instrument panel duct and demister duct assembly (4) into the instrument panel.

2. Install the passenger side instrument panel duct and demister duct assembly onto the outlets of the instrument panel. Make sure that the ducts are

correctly installed over the instrument panel and demister outlet seals.

3. Install the four screws that secure the passenger side instrument panel duct and demister duct assembly to the instrument panel. Tighten the screws

to 2.2 Nm (20 in. lbs.).

4. Position the driver side instrument panel duct and demister duct assembly (3) into the instrument panel.

5. Install the driver side instrument panel duct and demister duct assembly onto the outlets of the instrument panel. Make sure that the ducts are

correctly installed over the instrument panel and demister outlet seals.

6. Install the four screws that secure the driver side instrument panel duct and demister duct assembly to the instrument panel. Tighten the screws to 

2.2 Nm (20 in. lbs.).

7. Install the screw that secures the instrument panel top pad (1) to the reinforcement bracket (2). Tighten the screw to 2.2 Nm (20 in. lbs.).

8. Install the instrument panel.

Removal

REMOVAL

WARNING:  On vehicles equipped with airbags, disable the airbag system before attempting any steering wheel, steering column, or
instrument panel component diagnosis or service. Disconnect and isolate the battery negative (ground) cable, then wait two minutes for the
airbag system capacitor to discharge before performing further diagnosis or service. This is the only sure way to disable the airbag system.
Failure to take the proper precautions could result in accidental airbag deployment and possible personal injury or death.

NOTE:  Take the proper precautions to protect the front face of the instrument panel from cosmetic damage.

Duct-Floor Console|Page 8921 > < Duct-Floor Console|Page 8919