Durango 2WD V8-5.7L Hybrid (2009)
Hybrid Battery Service Switch: Service and Repair
High Voltage Service Disconnect - Removal
REMOVAL
WARNING: On vehicles equipped with the high voltage system, you must thoroughly read and follow all High Voltage Safety procedures. In
addition, before performing any diagnostic or service procedure near a high voltage component, you must perform the High
Voltage Power Down. Failure to follow these instructions may result in possible serious or fatal injury See: Service Precautions
1. Remove the drivers side high voltage battery access panel.
2. Service disconnect (1) as it is active in the vehicle.
3. Pull up on the service disconnect handle.