Suction and Discharge Line

Any kinks or sharp bends in the refrigerant plumbing will reduce the capacity of the entire air conditioning system. Kinks and sharp bends reduce the
flow of refrigerant in the system. A good rule for the flexible hose refrigerant lines is to keep the radius of all bends at least ten times the diameter of the
hose. In addition, the flexible hose refrigerant lines should be routed so they are at least 80 millimeters (3 inches) from the exhaust manifold.

High pressures are produced ill the refrigerant system when the air conditioning compressor is operating. Extreme care must be exercised to make sure
that each of the refrigerant system connections is pressure-tight and leak free. It is a good practice to inspect all flexible hose refrigerant lines at least 
once a year to make sure they are in good condition and properly routed.

WARNING:  REVIEW THE WARNINGS AND CAUTIONS BEFORE PERFORMING THE FOLLOWING OPERATION.

REMOVAL
1. Disconnect and isolate the battery negative cable.
2. Recover the refrigerant from the refrigerant system. Refer to:  Heating and Air Conditioning, Service and Repair, Refrigerant Recovery, See:

Service and Repair/Refrigerant Recovery

3. Unplug the wire harness connector from the high pressure cut-off switch.
4. Disconnect the refrigerant line couplers at the condenser and the suction line jumper. See Refrigerant Line Coupler in the Replacement for the

procedures. Install plugs in, or tape over all of the opened refrigerant line fittings.

5. Remove the nut that secures the refrigerant line support bracket near the compressor.

Suction And Discharge Line Remove/Install - Typical

6. Remove the screw that secures the refrigerant line manifold to the compressor. Install plugs in, or tape over all of the opened refrigerant line

fittings.

7. Remove the suction and discharge line assembly from the vehicle.

INSTALLATION
1. Remove the tape or plugs from all of the refrigerant line fittings. Install the refrigerant line couplers to the condenser and the suction line jumper.

See Refrigerant Line Coupler in the Replacement for the procedures.

2. Install the refrigerant line manifold to the compressor. Tighten the mounting screw to 22 N.m (200 in. lbs.).
3. Install the nut that secures the refrigerant line support bracket near the compressor.
4. Plug in the wire harness connector to the high pressure cut-off switch.
5. Connect the battery negative cable.
6. Evacuate the refrigerant system. Refer to:  Heating and Air Conditioning, Service and Repair, Refrigerant System Evacuate, Evacuating the

A/C System, See: Service and Repair/Refrigerant System Evacuate

7. Charge the refrigerant system. Refer to:  Heating and Air Conditioning, Service and Repair, Refrigerant System Charge, A/C System

Charge, See: Service and Repair/Refrigerant System Charge

A/C Discharge Hose/Line Replacement|Page 5870 > < A/C Discharge Hose/Line Replacement|Page 5868