expansion valve.

8. Lubricate new rubber O-ring seals with clean refrigerant oil and install them on the front liquid line rear and suction line fittings for the expansion

valve.

9. Connect the A/C liquid and suction lines to the expansion valve.

10. Install the nut that secures the A/C liquid and suction lines to the expansion valve. Tighten the nut to 23 N.m (17 ft. lbs.).
11. Remove the tape or plugs from the liquid line rear fitting and the receiver/drier outlet port.
12. Lubricate a new rubber O-ring seal with clean refrigerant oil and install it on the liquid line fitting.
13. Connect the liquid line fitting to the receiver/ drier outlet port.
14. Install the screw that secures the liquid line fitting to the receiver/drier. Tighten the screw to 11 N.m (97 in. lbs.).
15. Connect the wire harness connector to the A/C pressure transducer.
16. Install the drain tube to the wiper module.
17. Install the air cleaner housing and air inlet tube.
18. Reconnect the negative battery cable.
19. Evacuate the refrigerant system.
20. Charge the refrigerant system.