dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

PLG Module - Closes Liftgate But Will Not Open It|Page 23 > < PLG Module - Closes Liftgate But Will Not Open It
Page 2
background image

POLICY:
Reimbursable within the provisions of the warranty.

TIME ALLOWANCE:

FAILURE CODE:

Repair Procedure

PROCEDURE 1:
1.

Log onto the MDS2 System.

2.

Connect the MDS2 (Mopar Diagnostic System) and DRB III(R) (Scan Tool) to the vehicle and switch the ignition to "ON".

NOTE

AUTO CONNECTION WILL OCCUR ONCE THE DRB III(R), MDS2 AND VEHICLE ESTABLISH COMMUNICATION. THE "CANNOT
READ VIN FROM DRB III(R)" MESSAGE (ON THE MDS2) WILL BE REPLACED BY THE VEHICLE VIN. PRESS THE "OK" BUTTON
ON THE MDS2 TO REQUEST A MDS2 SESSION FOR THE VEHICLE VIN INDICATED. PRESS THE "OK" BUTTON WHEN ASKED TO
BEGIN SESSION.

3.

Push the FLASH tab on the MDS2.

4.

Select READ PART NUMBERS FROM VEHICLE and click SHOW UPDATES on the MDS2.

NOTE

A MESSAGE MAY APPEAR (AFTER STEP 3 OR 4) THAT INDICATES NO UPDATES ARE AVAILABLE. IF THIS OCCURS, MAKE SURE
YOUR DIAGNOSTIC EQUIPMENT IS OPERATING AT THE LATEST SOFTWARE LEVEL AS LISTED EARLIER IN THIS BULLETIN. IF
THE LATEST SOFTWARE IS INSTALLED, AND NO UPDATES ARE AVAILABLE, ANOTHER VEHICLE CONDITION EXISTS THAT
WILL REQUIRE FURTHER INVESTIGATION.

5.

Select the new software part number with the light pen and click UPDATE CONTROLLER SOFTWARE.

6.

The MDS2 and DRB III(R) will prompt for any operator action needed during the remainder of the reprogramming process.

NOTE:

INSTRUCTIONS ON THE DRB III(R) SCREEN WILL ASK FOR THE IGNITION KEY TO BE TURNED TO THE "LOCK" POSITION, THIS
MUST BE DONE WITHIN 15 SECONDS. SHORTLY AFTER THE IGNITION KEY IS PLACED IN THE "LOCK" POSITION,
REPROGRAMING WILL BEGIN. THE IGNITION KEY MUST REMAIN IN THE "LOCK" POSITION UNTIL THE DRB III(R) SCREEN
ASKS FOR THE KEY TO BE TURNED TO THE "ON" POSITION.

7.

Cycle the PLG open/close three times.

8.

If the flash procedure fails to correct the lift gate failure to move out of the primary latching position, go to DIAGNOSIS 2.

PROCEDURE 2A:
1.

Add three lift gate bumper shims, p/n 05020315AA, behind the rubber bumper on each side of the lift gate opening.

2.

Add or subtract lift gate bumper shims as required to achieve a consistent fit side to side.

3.

Power operate the PLG to open and then close with the RKE Fob or button in the overhead console to verity proper operation.

4.

Reset the PLG module obstacle detection values by cycling the PLG three times or by connecting the DRBIII(R) and selecting
Standalone/1998-2001 Diagnostics/Body/Power Lift Gate/Misc/Reset Module.

PROCEDURE 2B:

PLG Module - Closes Liftgate But Will Not Open It|Page 23 > < PLG Module - Closes Liftgate But Will Not Open It