Grand Caravan FWD V6-229 3.8L VIN L MFI (1997)
Audio Control Relay: Description and Operation
CIRCUIT OPERATION
This relay is located in the junction block and used along with the radio choke to control the switched battery feed to the amplifiers on the
speakers.
Power for the coil side of the relay is supplied on circuit X60. This circuit connects from the radio to the coil side of the relay and is HOT when
the radio is ON only.
Ground for the coil side of the relay is supplied on circuit Z1 and terminates at the left side cowl.
Power for the contact side of the relay is supplied on circuit X12. This circuit is protected by a 10 Amp fuse located in cavity 8 of the junction
block.
Battery voltage for the fuse is supplied on circuit A6. This circuit is HOT when the ignition switch is in the ACCESSORY and RUN position.
When the contacts in the relay CLOSE circuit X12 connects to circuit X1. Circuit X1 connects from the relay to the radio choke.