11. Remove brake pedal positioning tool.
12. Install the remote ground cable onto the ground stud located on left shock tower. Install the remote ground cable attaching nut and tighten to a
torque of 28 Nm (250 inch lbs.).
NOTE: The ICU may need to be initialized using the DRBIII scan tool after installation.
13. Bleed the base brakes and the ABS brakes hydraulic system.
14. Road test vehicle to ensure proper operation of the base and ABS systems.