dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Expansion Valve > < Component Locations|Page 6702
Page 1
background image

Evaporator Temperature Sensor / Switch: Service and Repair

REMOVAL

1. Open the hood and disconnect the negative battery cable remote terminal from the remote battery post.
2. Remove the right under panel silencer.
3. Disconnect the wiring connector for the evaporator probe.

Fig. 13 Evaporator Probe Needle

4. At the center of the HVAC housing, locate the evaporator probe access plate. Using a flat blade pry tool, pull back on the locking tab. Twist the

access plate counter clockwise one-quarter turn, and push the plate inside the HVAC housing.

5. Orient the plate in such a way that allows it to be pulled through the mounting hole, and remove it.
6. Pull the evaporator probe out of evaporator core.

INSTALLATION

The new probe must not go into the same hole (in the evaporator coil) that the old probe was removed.
1. The evaporator is manufactured with three holes for probe insertion. Insert the probe in the uppermost hole.
2. Insert the access plate inside the HVAC housing and orientate it so that the locking tab is one-quarter turn clockwise to where the tab snaps into

the HVAC case detent. Note that the plate will be flush with the outside of the HVAC housing.

3. Turn the plate one-quarter turn counter clockwise to seat the locking tab in the HVAC case detent.
4. Connect the wiring harness connector for the evaporator probe.
5. Install the right under panel silencer.
6. Connect the negative battery cable remote terminal to the remote battery post.