REFRIGERANT SYSTEM LEAKS
WARNING: REVIEW THE WARNINGS IN THE FRONT OF THIS SECTION BEFORE PERFORMING THE FOLLOWING
OPERATION.
If the refrigerant system is empty or low in refrigerant charge, a leak at any line fitting or component seal is likely. A review of the fittings, lines and
components for oily residue is an indication of the leak location. To detect a leak in the refrigerant system, perform one of the following procedures as
indicated by the symptoms.
EMPTY REFRIGERANT SYSTEM LEAK TEST
1. Evacuate the refrigerant system (minimum evacuation time of 15 mm.) to the lowest degree of vacuum possible (approx. 28 in. Hg). Determine if
the system holds a vacuum for at least 15 minutes after pump is OFF. If vacuum is held, a leak is probably not present. If system will not maintain
vacuum level, proceed with this procedure.
2. Prepare a 0.284 kg (10 oz.) refrigerant charge to be injected into the system.
3. Connect and dispense 0.284 kg (10 oz.) of refrigerant into the evacuated refrigerant system.
4. Proceed to Step 2 of Low Refrigerant Level Leak Test.
LOW REFRIGERANT LEVEL LEAK TEST
1. Determine if there is any (R-134a) refrigerant in the system.
2. Position the vehicle in a wind free work area. This will aid in detecting small leaks.
3. Bring the refrigerant system up to operating temperature and pressure. This is done by allowing the engine to run for five minutes with the system
set to the following:
-
Transaxle in Park
-
Engine Idling
-
A/C Controls Set in 100 % outside air (Recirculation position)
-
Blower switch in the high A/C position
-
A/C in the ON position
-
Open all windows
CAUTION: A leak detector designed for R-12 refrigerant may not detect leaks in a R-134a refrigerant system. Check specifications on leak
detector.
4. Shut off the vehicle and wait 2 - 7 minutes. Then use an Electronic Leak Detector that is designed to detect R-134a type refrigerant and search for
leaks. Fittings, lines, or components that appear to be oily usually indicates a refrigerant leak. To inspect the evaporator core for leaks, insert the
leak detector probe into the drain tube opening or a heat duct.
NOTE: If leak is not detected but known to exist, further diagnosis may be necessary using a refrigerant dye and the recovery machine. Refer to
recovery machine instructions for proper dye injection procedures.