SOME DISPLAY ITEMS READ "---"

This is caused by scrolling the DRB III display a single line up or down. The line which was scrolled onto the screen might read "---". Use the Page
Down or Page Up function to display the information.

DRB III Safety Information

DRB III SAFETY INFORMATION

WARNING:  EXCEEDING THE LIMITS OF THE DRB III MULTIMETER IS DANGEROUS. IT CAN EXPOSE YOU TO SERIOUS OR
POSSIBLY FATAL INJURY. CAREFULLY READ AND UNDERSTAND THE CAUTIONS AND THE SPECIFICATION LIMITS.

-

Follow the vehicle manufacturer's service specifications at all times.

-

Do not use the DRB III if it has been damaged.

-

Do not use the test leads if the insulation is damaged or if metal is exposed.

-

To avoid electrical shock, do not touch the test leads, tips, or the circuit being tested.

-

Choose the proper range and functions for the measurement. Do not try voltage or current measurement that may exceed the rated capacity.

-

Do not exceed the limits shown in the table.

-

Voltage between any terminal and ground must not exceed 500 VDC or 500 peak VAC.

-

Use cautio when measuring voltage above 25 VDC or 25 VAC.

-

Use the lo current shunt to measure circuits up to 10 A. Use the high current clamp to measure circuits exceeding 10 A.

-

When testing for the presence of voltage or current, make sure the meter is functioning correctly. Take a reading of a known voltage or current
before accepting a zero reading.

-

When measuring current, connect the meter in series with the load.

-

Disconnect the live test lead before disconnecting the common test lead.

-

When using the meter function, keep the DRBIII(R) way from spark plug or coil wires to avoid measuring error from outside interference.