dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Variable Induction Control Valve|Removal|Page 4033 > < Variable Induction Control Valve|Removal|Page 4031
Page 1
background image

Variable Induction Control Valve: Service and Repair
Installation

Short Runner Valve

INSTALLATION

1. Install o-ring.

2. Align tab on valve to slot in manifold and install.
3. Install mounting screws.
4. Tighten bolts to 2.8 Nm (25 in. lbs.).
5. Connect electrical connector and lock.
6. Install engine cover.
7. Connect negative battery cable.

Manifold Tuning Valve

3.5L

Variable Induction Control Valve|Removal|Page 4033 > < Variable Induction Control Valve|Removal|Page 4031