INSTALLATION
1. Install the dynamics sensor (1) over the studs mounted to the floor pan tunnel (4).
2. Working on each side of the floor pan tunnel (4), install the two mounting nuts (2). Tighten the nuts to 9 Nm (80 in. lbs.).
3. Connect the wiring harness connector (3) to the dynamics sensor (1).
4. Install the lower instrument panel trim on each side of console below the instrument panel.
5. Connect the battery negative cable to the battery post. It is important that this be performed properly. See: Starting and Charging/Battery/Service
and Repair/Procedures/Battery Reconnection
6. Perform the Verification Test and clear any faults. See: Brake Bleeding/Service and Repair