dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Differential Fluid - A/T > < Dodge Magnum V6-3.5L VIN V (2006)|Capacity Specifications|Page 1312
Page 1
background image

Coolant: Testing and Inspection

COOLANT CONCENTRATION TESTING

Coolant concentration should be checked when any additional coolant was added to system or after a coolant drain, flush and refill. The coolant
mixture offers optimum engine cooling and protection against corrosion when mixed to a freeze point of -37°C (-34°F) to -46°C (-50°F). The use of a
hydrometer or a refractometer can be used to test coolant concentration.

A hydrometer will test the amount of glycol in a mixture by measuring the specific gravity of the mixture. The higher the concentration of ethylene
glycol, the larger the number of balls that will float, and higher the freeze protection (up to a maximum of 60% by volume glycol).

A refractometer Tool 8286 will test the amount of glycol in a coolant mixture by measuring the amount a beam of light bends as it passes through the
fluid.

Some coolant manufactures use other types of glycols into their coolant formulations. Propylene glycol is the most common new coolant. However,
propylene glycol based coolants do not provide the same freezing protection and corrosion protection and is not recommended.

CAUTION:  Do not mix types of coolant - corrosion protection will be severely reduced.

Differential Fluid - A/T > < Dodge Magnum V6-3.5L VIN V (2006)|Capacity Specifications|Page 1312