13. Remove the strainers (1, 2) for the modulating pressure and shift pressure control solenoid valves from the valve housing.
14. Remove the strainer (1) in the inlet to torque converter lock-up control solenoid valve.
NOTE: A total of 12 valve balls are located in the valve body, four made from plastic (4) and eight from steel (1, 3).
15. Note the location of all check balls (1, 3, 4) and the central strainer (2) for re-installation. Remove all check balls (1, 3, 4) and the central strainer