Magnum V6-3.5L VIN V (2006)
responsible for the hydraulic control of the torque converter lockup clutch and distribution of the lubricating oil.
Overlap Regulating Valve
Each shift group is assigned one overlap regulating valve (1). The 1-2 / 4-5 overlap regulating valve is installed in the shift valve housing; the 2-3 and
3-4 overlap regulating valves are installed in the valve housing. The overlap regulating valve regulates the pressure reduction during a shift phase.
Command Valve
Command Valve
Each shift group possesses one command valve (3). The 1-2 / 4-5 and 2-3 command valves are installed in the shift valve housing, the 3-4 command
valve is installed in the valve housing. The command valve switches the shift group from the stationary phase to the shift phase and back again.
Holding Pressure Shift Valve