01 Relays and Modules02 Sensors and Switches03 Maintenance04 Engine, Cooling and Exhaust05 Powertrain Management06 Transmission and Drivetrain07 Brakes and Traction Control08 Starting and Charging09 Power and Ground Distribution10 Steering and Suspension11 Heating and Air Conditioning12 Restraint Systems13 Accessories and Optional Equipment14 Body and Frame15 Cruise Control16 Instrument Panel, Gauges and Warning Indicators17 Lighting and Horns18 Windows and Glass19 Wiper and Washer Systems
Dodge Magnum V8-5.7L (2008)03 · Maintenance
03 · Maintenance

Refrigerant: Service and Repair (page 2 of 3)

Make
Dodge
Model
Magnum
Engine
V8-5.7L
Year
2008
Section
Fluids › Refrigerant
MaintenanceService and Repair · page 2 of 3
background image

Refrigerant: Tools and Equipment

REFRIGERANT SYSTEM SERVICE EQUIPMENT

WARNING: Eye protection must be worn when servicing an A/C refrigerant system. Turn all valves off (rotate clockwise) on the equipment
being used before connecting or disconnecting service equipment from the refrigerant system. Failure to observe these warnings may result in
personal injury or death.

WARNING: Refer to the applicable warnings and cautions for this system before performing the following operation See: Heating and Air
Conditioning/Service Precautions/Warning and See: Heating and Air Conditioning/Service Precautions/Caution. Failure to follow the warnings
and cautions could result in possible personal injury or death.

When servicing the A/C system, an R-134a refrigerant recovery/recycling/charging station that meets SAE standard J2210 must be used (1). Contact an
automotive service equipment supplier for refrigerant recovery/recycling/charging equipment. Refer to the operating instructions supplied by the
equipment manufacturer for proper care and use of this equipment.

A manifold gauge set (1) may be needed with some recovery/recycling/charging equipment. The manifold gauge set should have manual shut-off valves
(2 and 6), or automatic back-flow valves located at the service port connector end of the manifold gauge set hoses (4 and 5). This will prevent refrigerant
from being released into the atmosphere.

MANIFOLD GAUGE SET CONNECTIONS

CAUTION: Do not use an R-12 manifold gauge set on an R-134a system. The refrigerants are not compatible and system damage will result.

Pinch or Ctrl + scroll to zoom. Double-tap to reset.

Parts & tools for this job For 2008 Dodge Magnum 5.7L

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.