Magnum V8-5.7L VIN 2 (2007)
Valve Deactivation Solenoid: Service and Repair
Solenoid-MDS
Removal
MULTIPLE DISPLACEMENT SOLENOID
Removal
1. Disconnect the negative battery cable.
2. Remove the intake manifold. See: Intake Manifold/Service and Repair
3. Remove foam insulator pad (1).
4. Remove wiring harness connectors (1) from the MDS solenoid(s) (2) that require removal.
5. Remove hold down bolt (3) from MDS solenoid(s) (2).
Caution: Do not try to pry the solenoid out. This could lead to breakage and contamination of the lubrication system.
6. Lightly tap on solenoid with a rubber mallet. Wiggle solenoid from side to side.
7. Remove MDS solenoid(s).
Installation