RAM 1500 Truck 4WD V8-4.7L (2008)
Alternator: Service and Repair
Generator - Removal
REMOVAL
3.7L / 4.7L
WARNING: Disconnect negative cable from battery before removing battery output wire (b+ wire) from generator. Failure to do so can result
in injury or damage to electrical system.
1. Disconnect negative battery cable at battery.
2. Remove generator drive belt.
3. Unsnap plastic insulator cap from B+ output terminal (3).
4. Remove B+ terminal mounting nut at rear of generator (2). Disconnect terminal from generator.
5. Disconnect field wire connector at rear of generator (4) by pushing on connector tab.
6. Remove 1 rear vertical generator mounting bolt (2).
7. Remove 2 front horizontal generator mounting bolts (1).
8. Remove generator from vehicle.