Hydraulic Control Assembly - Antilock Brakes: Service and Repair
RWAL Valve

RWAL VALVE

REMOVAL 

1. Install a prop rod on the brake pedal to keep pressure on the brake system.
2. Disconnect the battery cables from the battery.
3. Remove the battery.

4. Disconnect the electrical harness connector.
5. Remove the brake lines from the RWAL valve.
6. Remove RWAL valve mounting nuts and remove the RWAL valve.

INSTALLATION 

1. Install RWAL valve and Tighten the nuts to 15 Nm (11 ft. lbs.).
2. Install the brake lines to the RWAL valve and tighten to 19 Nm (170 inch lbs.).
3. Install the electrical harness connector to the RWAL valve and secure the connector.
4. Install the battery.
5. Install the battery cables to the battery.
6. Remove the prop rod on the brake pedal.
7. Bleed ABS brake system.