Ambient Temperature Sensor / Switch HVAC: Testing and Inspection

AMBIENT TEMPERATURE SENSOR TEST

1. Turn the ignition OFF.
2. Disconnect the ATS harness connector.
3. Measure the resistance of the ATS using the following min/max values:

 0° C  (32° F)

Sensor Resistance  = 29.33 - 35.99 Kilohms

10° C  (50° F)

Sensor Resistance  = 17.99 - 21.81 Kilohms

20° C  (68° F)

Sensor Resistance  = 11.37 - 13.61 Kilohms

25° C  (77° F)

Sensor Resistance  = 9.12 - 10.86 Kilohms

30° C  (86° F)

Sensor Resistance  = 7.37 - 8.75 Kilohms

40° C  (104° F)

Sensor Resistance  = 4.90 - 5.75 Kilohms

The sensor resistance should read between these min/max values. If the resistance values are not OK, replace the Sensor.