dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Recall - Blower Motor Overlay Harness Installation|Page 5627 > < Recall - Blower Motor Overlay Harness Installation|Page 5625
Page 3
background image

5.

Disconnect the installment panel (I/P) wiring harness 74-way connector (Figure 1 ).

6.

Release the RED CPA, lift the WHITE lock bar on the top of the 14-way ignition switch connector and then disconnect the connector (Figure 2).

7.

Release the four (4) BLUE wedge clips from the back (wire) side of the ignition switch connector and then remove the wedge completely using
pliers (Figure 2).

8.

Remove the PINK with BLACK tracer wire from the ignition switch connector (Figure 2).

Recall - Blower Motor Overlay Harness Installation|Page 5627 > < Recall - Blower Motor Overlay Harness Installation|Page 5625