Expansion Valve: Testing and Inspection

FIXED ORIFICE TUBE

The fixed orifice tube can be checked for proper operation using the following procedure. However, the fixed orifice tube is only serviced as a part of
the liquid line unit. If the results of this test indicate that the fixed orifice tube is obstructed or missing, the entire liquid line unit must be replaced.

WARNING:  THE LIQUID LINE BETWEEN THE CONDENSER OUTLET AND THE FIXED ORIFICE TUBE CAN BECOME HOT
ENOUGH TO BURN THE SKIN. USE EXTREME CAUTION WHEN PERFORMING THE FOLLOWING TEST.

1. Confirm that the refrigerant system is properly charged.
2. Start the engine. Turn on the air conditioning system and confirm that the compressor clutch is engaged.
3. Allow the air conditioning system to operate for five minutes.
4. Lightly and cautiously touch the liquid line near the condenser outlet at the front of the engine compartment. The liquid line should be hot to the

touch.

5. Touch the liquid line near the evaporator inlet at the rear of the engine compartment. The liquid line should be cold to the touch.
6. If there is a distinct temperature differential between the two ends of the liquid line, the orifice tube is in good condition. If there is little or no

detectable temperature differential between the two ends of the liquid line, the orifice tube is obstructed or missing and the liquid line must be
replaced.