dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Leak Detection Pump, Evaporative System|Specifications|Page 2845 > < Leak Detection Pump, Evaporative System|Specifications|Page 2843
Page 3
background image

Keep in mind that if the purge solenoid seat is leaking, it could go undetected since the leak would end up in the intake manifold. Disconnect the purge
solenoid at the manifold when leak checking. In addition, a pinched hose fault (P1486) could set if the purge solenoid does not purge the fuel system
properly (blocked seat). The purge solenoid must vent the fuel system prior to the LDP system test. If the purge solenoid cannot properly vent the
system the LDP cannot properly complete the test for P1486 and this fault can set due to pressure being in the EVAP system during the test sequence.

Multiple actuation's of the DRB III(R) Leak Detection Pump (LDP) Monitor Test can hide a 0.020 leak because of excess vapor generation.
Additionally any source for additional vapor generation can hide a small leak in the EVAP system. Excess vapor generation can delay the fall of the
LDP diaphragm thus hiding the small leak. An example of this condition could be bringing a cold vehicle into a warm shop for testing or high ambient
temperatures.

Fully plugged and partially plugged underhood vacuum lines have been known to set MIL conditions. P1494 and P0456 can be set for this reason.
Always, thoroughly, check plumbing for pinches or blockage before condemning components.

TEST EQUIPMENT The Evaporative Emission Leak Detector (EELD) Miller Special Tool 8404 is capable of visually detecting leaks in the
evaporative system and will take the place of the ultrasonic leak detector 6917A. The EELD utilizes shop air and a smoke generator to visually detect
leaks down to 0.020 or smaller. The food grade oil used to make the smoke includes an UV trace dye that will leave telltale signs of the leak under a
black light. This is helpful when components have to be removed to determine the exact leak location. For detailed test instructions, follow the
operators manual packaged with the EELD.

NOTE:  Be sure that the PCM has the latest software update. Reprogram as indicated by any applicable Technical Service Bulletin. After LDP repairs
are completed, verify the repair by running the DRB III(R) Leak Detection Pump (LDP) Monitor Test as described in Technical Service Bulletin
18-12-99.

Leak Detection Pump, Evaporative System|Specifications|Page 2845 > < Leak Detection Pump, Evaporative System|Specifications|Page 2843