dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Electrical Specifications|Page 5015 > < Electrical Specifications|Page 5013
Page 2
background image

Fig. 5 Generator Connectors - Typical Bosch

Fig. 6 Generator Connectors - Typical Denso

5. Remove B+ terminal mounting nut at rear of generator (Fig. 5) or (Fig. 6). Disconnect terminal from generator.
6. Disconnect field wire connector at rear of generator by pushing on connector tab.
7. Remove generator from vehicle.

INSTALLATION

1. Position generator to engine and snap field wire connector into rear of generator.
2. Install B+ terminal eyelet to generator stud. Tighten mounting nut to 12 Nm (108 in. lbs.) torque.
3. Install generator mounting fasteners and tighten as follows:

-

Generator mounting bolt ..........................................................................................................................................................  41 Nm (30 ft. lbs.)

-

Generator pivot bolt/nut ...........................................................................................................................................................  41 Nm (30 ft. lbs.)

CAUTION:  Never force a belt over a pulley rim using a screwdriver. The synthetic fiber of the belt can be damaged.