dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Evaporator Core|Service and Repair > < Combination Coil
Page 1
background image

Evaporator Core: Description and Operation
Evaporator Coil

SYSTEM OPERATION

Front

The evaporator coil is located in the heater-A/C housing, on the right side of the engine compartment. The evaporator coil is positioned in the
heater-A/C housing so that all air that enters the housing must pass over the fins of the evaporator before it is distributed through the system
ducts and outlets. However, air passing over the evaporator coil fins will only be conditioned when the compressor is engaged and circulating 
refrigerant through the evaporator coil tubes.

Refrigerant enters the evaporator from the expansion valve as a low-temperature, low-pressure mixture of liquid and gas. As air flows over the
fins of the evaporator, the humidity in the air condenses on the fins, and the heat from the air is absorbed by the refrigerant. Heat absorption
causes the refrigerant to boil and vaporize. The refrigerant becomes a hightemperature, low-pressure gas before it leaves the evaporator.

The evaporator coil cannot be repaired and, if faulty or damaged, it must be replaced.

Rear

Models equipped with the optional rear heater-A/C unit have a combination coil located within the rear unit housing. The combination coil
functions as both the rear heater core and the rear evaporator coil. See Combination Coil in the Description and Operation for more
information.

Evaporator Core|Service and Repair > < Combination Coil