dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Thermostat Housing, Engine Cooling > < Thermostat - Diesel Engine Overheating|Page 2324
Page 3
background image

5. Position generator to thermostat housing. Install and tighten mounting bolt to 24 Nm torque. Tighten pivot bolt to 43 Nm (32 ft. lbs.) torque.

6. Install the check valve hose and hose clamp at thermostat housing.

7. Install accessory drive belt.

8. Connect negative battery cables to both batteries.

9. Fill cooling system and check for leaks.

Thermostat Housing, Engine Cooling > < Thermostat - Diesel Engine Overheating|Page 2324