dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Relays and Modules - Restraint Systems > < Main Relay (Computer/Fuel System)|Locations|Page 591
Page 2
background image

± 5 ohms.

3. Connect the ohmmeter between terminals 30 and 87A. The ohmmeter should show continuity between terminals 30 and 87A.
4. Connect the ohmmeter between terminals 87 and 30. The ohmmeter should not show continuity at this time.
5. Connect one end of a jumper wire (16 gauge or smaller) to relay terminal 85. Connect the other end of the jumper wire to the ground side of a 12

volt power source.

6. Connect one end of another jumper wire (16 gauge or smaller) to the power side of the 12 volt power source. Do not attach the other end of the

jumper wire to the relay at this time.

WARNING: DO NOT ALLOW OHMMETER TO CONTACT TERMINALS 85 OR 86 DURING THIS TEST. DAMAGE TO
OHMMETER MAY RESULT.

7. Attach the other end of the jumper wire to relay terminal 86. This activates the relay. The ohmmeter should now show continuity between relay

terminals 87 and 30. The ohmmeter should not show continuity between relay terminals 87A and 30.

8. Disconnect jumper wires.
9. Replace the relay if it did not pass the continuity and resistance tests. If the relay passed the tests, it operates properly. Check the remainder of the 

ASD and fuel pump relay circuits.